CHECK Battery charge level
t
IMPORTANT
t
If there is doubt about the battery charge, refer to the maintenance personnel.
Do not use the platform if the battery charge level is lower than 30%.
- Switch the platform on.
- Check the battery charge level
A
displayed on the LCD indicator. Consult the
maintenance personnel if the charge level is low.
- Turn the platform off.
CHECK Battery fluid level
t
IMPORTANT
t
At all times, make sure that:
- The positive terminals cannot come into contact with the negative terminals.
- The positive terminals cannot come into contact with metallic parts of the platform.
Do not add distilled water if the battery charge level is not 100%.
The battery contains a highly corrosive liquid. Always wear protective clothing, safety gloves, and goggles or a face
shield during maintenance. Avoid contact with any part of the body or clothing at all times. Rinse any exposed area
with clean water and seek medical advice.
Clean and dry the battery cell caps before closing them.
- Remove the right and left battery covers
1
.
- Open one of the battery cell caps
2
.
- The level is correct when the liquid reaches the top of the filter
3
.
- If the level is low:
• Add distilled water until the correct level is reached.
• Close the battery cell cap.
- If the level is correct:
• Close the battery cell cap.
- Repeat these steps for all the battery cells.
- Put the battery covers
1
back in place.
3 - 13
2
3
1
A
647536 (26/11/2020)
150 AETJ/AETJ 3D - 150 AETJ C/AETJ C 3D - 170 AETJ L