RESET Maintenance warning
Illustration = second version.
NOTE: It is not possible to reset the maintenance warning if it is not displayed. The
warning may need to be reset even if no maintenance has been performed, e 2-
DESCRIPTION: DESCRIPTION OF THE MULTI-FUNCTION DISPLAY: MAINTENANCE
WARNING.
NOTE: The platform should be in transport position. The platform must not be on
a steep slope.
- Switch the platform on.
- Wait for the audible alarm to sound once.
NOTE: The procedure described below must be performed within 3 seconds of the
audible alarm sounding. Otherwise, repeat the procedure from the beginning.
- Press and hold down the activation button
1
.
- Push and hold the switches
2
and
3
down until the maintenance/fault alarm
light
4
goes out, the information "Maintenance"
A
should no longer be displayed.
- Turn the platform off.
3 - 28
4
SEVCON
1
2
3
A
647536 (26/11/2020)
150 AETJ/AETJ 3D - 150 AETJ C/AETJ C 3D - 170 AETJ L