9
MEZZER SERVICE MANUAL
AIR SPRING SERVICE
1
2
3
Mezzer Pro: Remove IRT air cap.
Make sure the air is released from
the fork. Depress IRT Schrader
Valve with a 2mm hex a few times
to ensure all air is released.
Mezzer Expert: Skip to Step 2.
Mezzer Pro: Using a standard
cassette tool and 1” socket loosen
IRT cap until threads are free from
leg.
Mezzer Expert: Using a 24mm
socket loosen IVA cap until threads
are free from leg.
Mezzer Pro: Pull IRT assembly
straight out, Clean with isopropyl,
Inspect seal for damage. If needed
Replace IRT piston seals (141-
36713-K026).
Mezzer Expert: Pull IVA assembly
straight out, Clean with isopropyl,
Inspect seal for damage. If needed
replace IVA piston seals (141-
36713-K026).