CLEAN Dry air filter cartridge
In very dusty atmospheres, the cartridge cleaning frequency must be reduced to 10 hours.
However, there are pre-filtration elements (
FILTER CARTRIDGES AND BELTS); if necessary., contact your dealer.
IMPORTANT
If the clogging indicator light comes on, this operation must be carried out as quickly as possible (1 hour maximum).
The cartridge must not be cleaned more than seven times, after which it must be replaced.
Never use the lift truck without an air filter or with a damaged air filter.
- Open the engine cover ( DESCRIPTION: INSTRUMENTS AND CONTROLS).
- Release the locks 1 and remove the cover 2.
- Gently remove the cartridge 3 taking care to avoid spilling the dust.
- Leave the safety cartridge in place.
- Using a compressed air jet (max. 3 bar), clean the filter cartridge from the top to the bottom and from the inside towards
the outside, maintaining a minimum safety distance of 30 mm to avoid damaging the cartridge. Cleaning is completed
when there is no more dust escaping from the cartridge.
IMPORTANT
The cartridge must not be blown anywhere near the air filter box.
Never clean the cartridge by tapping it against a hard surface.
Never wash the dry air filter cartridge.
Never clean the air filter security cartridge; replace it with a new one if it is dirty or damaged.
- Clean the cartridge seal surfaces with a damp, clean lint-free cloth and grease with a silicone lubricant (MANITOU part
no.: 479292).
- Check visually the outer condition of the air filter and its attachments.
- Check also the condition of the hoses and their attachments.
CLEAN Radiator core
IMPORTANT
In a polluting atmosphere, clean the radiator core every day. Do not use a water jet or high-pressure steam as this
could damage the radiator fins.
- Unscrew the thumbscrews 1 and remove the housing 2.
- Lift cover 3 to gain access to the radiator.
- Using a soft cloth, clean the radiator in order to remove as much dirt as possible.
- Clean the radiator with jet of compressed air directed from the inside towards the
outside. This is the only effective way of removing impurities (opposite direction
to the cooling air flow).
1
1
2
3
3 - 21
647650 (19/02/2018)
M
I-X 50L/60/70 D C ST3A S2 / MI 50L/60/70 D ST3B S2 / MI 50L/60/70 G S2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitou MI-X 50L D C ST3A S2 and is the answer not in the manual?

Manitou MI-X 50L D C ST3A S2 Specifications

General IconGeneral
BrandManitou
ModelMI-X 50L D C ST3A S2
CategoryLifting Systems
LanguageEnglish

Related product manuals