3. Boom raises
slowly.
a. Low hydraulic oil level. a. Check system for leaks. Make repairs
as needed. Fill reservoir.
b. Low engine rpm. b. Increase and maintain engine rpm.
c. Damaged relief valve. c. Repair or replace relief valve.
d. Extremely cold hydraulic oil. d. Operate unit to bring oil to operating
temperature.
e. Improper hose or fittings, installed. e. Replace hose or fittings. (Refer to
Manitowoc Crane Care Parts Manual).
f. Operating two functions with in the
same control valve bank assembly.
f. Feather controls to obtain desired
speed of both functions.
g. Restriction in return hose. g. Replace return hose.
h. Cylinder piston seals leaking. h. Replace all cylinder seals.
i. Scored cylinder barrel. i. Hone or replace barrel.
j. Worn hydraulic pump section. j. Repair or replace pump section.
4. Boom lowers
slowly.
a. Low hydraulic oil level. a. Check system for leaks. Make repairs
as needed. Fill reservoir.
b. Low engine rpm. b. Increase rpm to recommended level.
c. Damaged relief valve. c. Repair or replace relief valve.
d. Operating two functions within the
same control valve bank assembly.
d. Feather controls to obtain desired
speed of both functions.
e. Extremely cold hydraulic oil. e. Operate unit to bring oil to operating
temperature.
f. Improper hose or fittings installed. f. Replace hose or fittings. (Refer to
Manitowoc Crane Care Manual).
g. Restriction in return hose. g. Replace return hose.
h. Cylinder piston seals worn. h. Replace all cylinder seals.
i. Scored cylinder barrel. i. Hone or replace barrel.
j. Worn hydraulic pump section. j. Repair or replace pump section.
k. Piston rod broken (loose from piston). k. Replace piston rod and all cylinder
seals.
5. Boom will not
ra
ise. a. Low hydraulic oil. a. Check system for leaks. Make repairs
as needed. Fill reservoir.
b. Main relief valve or circuit relief valve
damaged.
b. Repair or replace relief valve.
c. Excessive load. c. Reduce load as required.
d. Worn or damaged hydraulic pump
section.
d. Repair or replace pump section.
e. Broken pump shaft. e. Replace pump shaft and seals.
f. Broken pump drive coupling. f. Replace drive coupling.
g. Broken control valve spool. g. Replace control valve.
Symptom Probable Cause Solution
Reference Only

Table of Contents

Other manuals for Manitowoc Grove GRT880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT880 and is the answer not in the manual?

Manitowoc Grove GRT880 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT880
CategoryConstruction Equipment
LanguageEnglish

Related product manuals