9-23
GRT880 SERVICE MANUAL MAINTENANCE AND LUBRICATION
9
Published 10/19/2017, Control # 618-00
GROVE
Boom (Continued)
NOTE: Crane Setup: Machine shall be set up on firm level surface with fully extended outriggers and 9979 kg (22,000 lb)
counterweight installed. Ensure crane is level.
Boom must be directly over the front with house lock engaged.
Set boom angle at zero degrees (0°).
All lubrication points can be accessed by operating crane in the 0001 RCL mode using B boom configuration.
CAUTION: Do not operate crane in RCL bypass to lubricate the boom.
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Lube Capacity Lube Interval Application
83
Telescope
Cylinder Wear
Pads
Figure 9-12
and
Figure 9-13
L
Coat
thoroughly.
Apply grease at
assembly or tear-down.
Brush on.
84
Internal Side and
Bottom Wear
Pads - Inner
Sections
Figure 9-12
and
Figure 9-13
L
Thoroughly
coat all areas
wear pad
moves on.
250 hours or 3 months*. 23 locations.
85A
Boom Section
Rear Upper
Wear Pads - Tele
1
Figure 9-12
and
Figure 9-13
L
Until grease
extrudes.
50 hours or 1 week*.
2 grease fittings.
See note
immediately below.
NOTE: In Auto Mode B, extend boom to 21 m (68.9 ft) to align access holes with grease fittings.
85B
Boom Section
Rear Upper
Wear Pads - Tele
2
Figure 9-12
and
Figure 9-13
L
Until grease
extrudes.
50 hours or 1 week*.
2 grease fittings.
See note
immediately below.
NOTE: In Auto Mode B, extend boom to 38.5 m (126.3 ft) to align access holes with grease fittings.
85C
Boom Section
Rear Upper
Wear Pads - Tele
3
Figure 9-12
and
Figure 9-13
L
Until grease
extrudes.
50 hours or 1 week*.
2 grease fittings.
See note
immediately below.
NOTE: In Auto Mode B, extend boom to 38.31 m (125.7 ft) to align access holes with grease fittings.
86
Boom Section
Lower & Upper
Wear Pads
Figure 9-12
and
Figure 9-13
L
Thoroughly
coat all areas
wear pad
moves on.
50 hours or 1 week*. 12 locations.
87
Extend Cable
Sheaves
Figure 9-12
and
Figure 9-13
A
Until grease
extrudes.
250 hours or 3 months.
6 grease fittings.
Extend boom to
align access holes
with grease
fittings.
88 Tele 1 Rollers
Figure 9-12
and
Figure 9-13
L
Apply grease to
shaft or inner
roller surfaces.
250 hours or 3 months. 1 location.
NOTE: *Lubricate items more frequently than interval in table if environmental conditions and/or operating conditions
require.
CAUTION: Do not apply excessive pressure or force when greasing wear pads. This can cause grease fitting to separate
from wear pad. Only apply grease until resistance is felt.
Reference Only

Table of Contents

Other manuals for Manitowoc Grove GRT880

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT880 and is the answer not in the manual?

Manitowoc Grove GRT880 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT880
CategoryConstruction Equipment
LanguageEnglish

Related product manuals