MODEL YB8 INSTALLATION AND OPERATION
April 1999/Manning Environmental Inc.
Page A-1
Introduction
Congratulations on the purchase of a Manning Environmental, Inc. Model YB8 Sampler. The model
selected is the latest in a long line of state of the art equipment produced for over twenty three years by
Manning Environmental Inc. Based on this experience, if there is one thing Manning can claim it is that we
know samplers. T here are Manning samplers still used in regular service t oday that are o ver twenty years
old. I t is almost impossible t o find an organization with t he commitment of producing equipment with such a
history o f reliability, dependability, quality and value as exhibited by Manning samplers. E ven so,
improvement is a never ending goal at Manning. We are always interested in the perceptions and experiences
of our users. If there are any suggestions or comments on our equipment, this manual, or anything Manning
does, please feel free to contact us.
The YB8 is a stationary peristaltic pump based model which can automatically collect and hold Non-Toxic,
Toxic, and Suspended Solid samples from a liquid source. The unit was designed from the ground up with
active user participation to ensure the features and options that are important to field use were incorporated
into the unit. It employs a high speed, peristaltic pump to draw the samples and an industrial grade
refrigeration unit to cool and maintain them at the EPA recommended 4 C. Backed by Manning’s reputation
0
for quality and dependability, it will provide years of reliable service.
Even if t he sampler will not be used immediately upon receipt, unpack and examine it. This will help to
familiarize t he user with t he equipment. V erify that all o f t he parts have been received and that no damage
has o ccurred in shipment. I f damage is noticed, immediately report the extent of it t o both the transportation
company and to Manning Environmental Inc. In addition, check the packing list to verify that it matches the
items sent and that all accessories ordered are included with the shipment. Manning strives for 100 percent
accuracy in the delivery of our equipment, but even with the most stringent quality assurance, mistakes do
occur. O missions, damage, or mistakes must be reported to Manning Environmental Inc. within 10 working
days of receipt of the shipment.
This manual is designed to communicate a complete understanding of the equipment, its operation,
maintenance, and functions. Manning recommends this manual and the equipment be examined completely
before placing t he unit into service. M anning’s commitment to producing reliable, top quality products is
legendary, but t he possibility of breakdown or malfunction always exists. T his manual should enable the
diagnosis and solving of many potential problems. If the problem cannot be solved, please feel free to call
our service department at 1-800-863-9337 to obtain help. Our first priority is making sure the experience
with Manning equipment is an excellent one. In almost all instances the difficulty can be addressed over the
phone, but in the rare instance it cannot, the equipment may need to be sent back to Manning for service.
Please contact our customer service department at 1-800-863-9337 to obtain a Return Authorization
Number. T hen fo llow t he shipping instructions that will be given. P lease note t he malfunction on the paper
work so a diagnosis and a solution to the problem can be arrived at with the least amount of delay.
We recommend the following steps before attempting to use the sampler:
1. Review this manual. Read the errata sheets at the end of this manual for the latest updates.
2. Follow the instructions beginning on page 1-8 to assemble the YB8.
3. Set the time and activate a test cycle.