EasyManua.ls Logo

Marantz SR 8015 - Page 97

Marantz SR 8015
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YES
NO
NO
(15) Are a picture and sound output when a dif-
ferent TV is used?
Check the Firmware.
Is "IP SCALER ERR" displayed?
Check the unit.
The TV is faulty.
Check the circuits around the IP SCALER [U2800,
DIGITAL PCB] and DDR2 [U3000/U3001].
If there appear to be no problems, [U2800] or
[U3000/U3001] is faulty.
See "HDMI "Rx/Tx" Failure Detection"
97
Before Servicing
This Unit
Electrical Mechanical Repair Information Updating

Related product manuals