15
The low battery level can be detected when the unit works without main power supply.
Should the battery power rise again above 11,5V ZEUS4-MC LITE sends an SMS message with
the following text: “Low Battery restored”.
The “Low battery” event is send when the ZEUS4-MC LITE operates only with a
backup battery and it is not connected on the Main Power Supply.
Parameter MAIN determinates time out control after which the ZEUS4-MC LITE will send “Main
Power Lost alarm”. Time can be set between 1 and 9999 seconds.
Parameter BATT determinates time out control after which the ZEUS4-MC LITE will send Battery
power level notifications. Time can be set between 1 and 9999 seconds.
Table of parameters:
Battery Power Lost filter
Table 13: MAIN, BATT parameters
Example:
Direct programming on the SIM card
ZEUS4-MC LITE PROGRAMMING TABLE
Main power must be down 5s to send alarm.
Battery level must be stable for 20s to send alarm.
Table 14: MAIN, BATT parameters example
Remote programming by SMS
;MAIN=5;BATT=20;
10.2.7 OS parameters
ZEUS4-MC LITE device has 2 open collector outputs and each of them can be programmed in a
different way: as a bi-stable or mono-stable (pulse) output. The programming time is in seconds.
Typical connection for the output: