Max number of alarm events on input 1
System block time on input 1
Max number of alarm events on input 2
System block time on input 2
Table 20: IT, AR and IB parameters example
Remote programming by SMS
;IT1=125;AR1=10;IB1=600; IT2=720;AR2=5;IB2=3600;
Arm/disarm events on ZEUS4-MC LITE resets bypass function.
10.2.10 Alarm SMS reporting
The default message text is English, but it is possible to change language with LNG parameter. In
addition user can customize a short SMS message text for each alarm input.
Each message is built from 3 parts and user can write the first (User Location) and the second
(alarm event) part of the message. Unit adds the third part (alarm event description) automatically.
Language of the 3rd part may be changed by LNG parameter. The message is stored in the SIM
phone book so you should add any number for correct operation.
Table 21: Alarm SMS formatting
Message should not be longer than 14 characters! Space is also counted as one
character.
Example:
Remote programming by SMS
;#0USER LOCATION=0;#1INPUT 1=1;#2INPUT 2=2;
10.2.11 DTMF REMOTE COMMANDS
When ZEUS4-MC LITE enters VOICE call in alarm report function user has the option to control
device via DTMF command. By default this DTMF control is limited to canceling the ongoing and
all next call.