ZEUS4-MC LITE PROGRAMMING TABLE
Alarm on IN1 trigger output 1
No direct connection between input2 and output
GSM network failure on output 2
System tamper on output 4
Table 18: OD parameters example
Remote programming by SMS
;OD1=1;OD2=0;OD6=2;OD7=4;
10.2.9 IT, AR and IB parameters
With these parameters user define the number of alarm events that can be triggered in chosen
interval before the systems goes in bypass mode (blocks sending alarm events to telephone
numbers).
IT – parameter defines the interval (in seconds) in which maximum AR number of alarm can be
triggered.
AR – parameter defines the maximum number of alarms trigged in IT time
IB – IB parameter defines how long (in seconds) sending of alarm events is blocked when
automatic input block system in enabled.
Table of parameters:
Maximum allowed number of events on 1
st
input
Maximum allowed number of events on 2
nd
input
System block time on 1
st
input
System block time on 2
nd
input
Table 19: IT, AR and IB parameters
Example:
Input 1 will be blocked for 10 minutes if 10 alarm events are triggered within 125 seconds
Input 2 will be blocked for 1 hour if 5 alarm events are triggered within 12 minutes.
Direct programming on the SIM card
ZEUS4-MC LITE PROGRAMMING TABLE