EasyManua.ls Logo

Marsh-McBirney Flo-Mate 2000 - Fpa;Rc Time

Marsh-McBirney Flo-Mate 2000
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
rC
The display will show the letters rC when you first switch to the time constant mode. The display will
start with unfiltered full scale velocities. These readings are accurate but may bounce around slightly.
As the filtering takes effect, the readings will settle out. It takes five time constants to get to maximum
filtering. There is no time bar on the rC display because the display is continually up-
dated.
FPA/rC Time
The FPA and rC time is specified in seconds. The 5 key increments time and the 6 key decrements
time. The display will show the FPA/rC length in seconds. After you have reached the desired setting,
wait and the display will automatically switch to velocity.
Comment:
Limits are 2-120 seconds for FPA and 2-30 seconds for rC.Changing FPA and rC time restarts the
filtering.