40 MAC 575 Krypton
Display messages
Message Appears when... What to do
(Reset)
... the fixture is indexing effects at startup. Wait for reset to complete.
(Serial reset) ... the fixture has received a reset command.
Wait for reset to complete. Note that
you can set
→ to
to prevent accidental DMX reset
commands.
... the effects have been indexed and are
moving to their default positions.
Wait a few moments.
...the lamp access cover is not fully closed.
Check that the lamp access cover is
locked in place.
(Lamp error)
... the lamp does not ignite within 30 seconds
of receiving the ‘Lamp ON’ command. Likely
reasons are a missing or defective lamp, or
insufficient AC voltage.
Check the lamp. Check that the voltage
and frequency settings match the local
supply.
(Light sensor 1 error) ... there is an error in the light sensor circuit.
(Lamp hot) ... the lamp is too hot to restrike.
Allow up to ten minutes for the lamp to
cool enough for it to restrike.
...the fixture is below the minimum
temperature for the lamp to strike.
Leave the fixture powered on for a
while to generate a little internal heat.
Increase the ambient temperature.
(Memory error) ...the EEPROM memory cannot be read.
Contact Martin service personnel for
assistance.
(Check-sum error)
...a software upload is unsuccessful. Reload software.
... there is no communication between the
control panel and motherboard. This readout
appears briefly when switching on the fixture.
Check fuses and replace accordingly.
Check that cable between control panel
and motherboard is connected
properly. Reinstall software.
(Short error)
... the fixture detects the lamp is ON but no
‘Lamp ON’ command has been received. This
can occur if the lamp relay is stuck or if the
lamp-power feedback circuit fails. The fixture
may be operated but remote lamp on/off may
be affected.
Contact Martin service personnel for
assistance.
(Base temperature sensor error)
(Lamp temperature sensor error)
(Switchmode/ballast side
temperature sensor error)
...there is a malfunction in the temperature
sensing circuit.
Contact Martin service personnel for
assistance.
(Feedback error pan)
(Feedback error tilt)
(Feedback error pan/tilt)
...there is a malfunction in the optical pan/tilt
monitoring circuit (e.g. sensor defective). After
a time-out, the effect in question stops in a
random position.
Reset fixture. Contact Martin service
personnel if problem continues.
(Lamp temperature cut-out)
... the lamp temperature is too high and
thermal protection circuits cut power to the
lamp.
Allow fixture to cool. Ensure nothing is
obstructing airflow around fixture.
Clean air vents, air filters and fans.
Reduce ambient temperature.
Contact Martin service personnel if
problem continues.
(Pan time-out)
(Tilt time-out)
(Focus time-out)
(Zoom time-out)
...there is a malfunction in the electric indexing
circuit for pan, tilt, focus or zoom. The fixture
will, after the time-out, establish a mechanical
stop, and continue to work normally.
Reset fixture. Contact Martin service
personnel if problem continues.
(Color wheel 1 time-out))
(Color wheel 2 time-out))
(Gobo wheel 1 time-out)
(Gobo wheel 2 time-out)
(Gobo wheel rotation time-out)
...there is a malfunction in the
magnetic-indexing circuit (e.g. sensor
defective or magnet missing). After the
time-out, the effect in question stops in a
random position.
Reset fixture. Contact Martin service
personnel if problem continues.
(Driver current error)
(Real-time clock error)
(Display programming error)
...there is a software error.
Reset fixture. Contact Martin service
personnel if problem continues.
Table 6: Display messages