22 MAC Viper Profile User Guide
DMX protocol
Applicable when running MAC Viper Profile firmware version: 1.3.0
Basic
16-bit
Mode
16-bit
Extended
Mode DMX Value Percent Function
Fade
type
Default
value
11
0 - 19
20 - 49
50 - 200
201 - 210
211 - 255
0 - 7
8 - 19
20 - 78
79 - 82
82 - 100
Strobe/shutter
Shutter closed (Lamp switches to 800 watt mode after shutter is closed
for 10 seconds)
Shutter open
Strobe, slow fast
Shutter open
Random strobe, slow fast
Snap 30
2
2
0 - 65535 0 - 100
Dimmer fade (MSB)
Closed open
Fade 0
3
Dimmer fade, fine (LSB) Fade 0
34
0 - 255 0 - 100
Cyan
White full cyan
Fade 0
45
0 - 255 0 - 100
Magenta
White full magenta
Fade 0
56
0 - 255 0 - 100
Yellow
White full yellow
Fade 0
67
0 - 255 0 - 100
CTO
Open (6000 K) warm (3200 K)
Fade 0
Table 1: DMX Protocol