6.21 PERIOD CHECKS AND MAINTENANCE
Perform service at intervals indicated
Before
starting
Every 50
hrs.or 1
Month
Every 200
hrs.or 3
Month
Every 400
hrs.or 6
Month
Every 500
hrs.or Yearly
Every 1000
hrs.or Yearly
Every 2000
hrs.or Yearly
Fuel system
Check the fuel level and refill
Remove sediment from fuel tank
Water/fuel separator drainage
Clean the water/fuel separator
Replace the fuel filter element
Check the fuel injection nozzle
Check the fuel injection timing
Check the fuel injection pump
Lubrification system
Check the oil level
(Before
operation
)
Replace the oil
1
st
time
(and
thereafter
)
Replace the oil filter element
1
st
time
(and
thereafter
)
Cooling system
Check and eventually add the liquid cooling
Replace the the liquid cooling
Inspect exhaust system components
for cracks and corrosion (exhaust line, hose
clamps, silencer and outlet flapper)
Check function of siphon break
(if equipped)
○○
Adjust seawater pump belt tension
1
st
time
(and
thereafter
)
Replace seawater pump impeller
Check condition of heat exchanger
anticorrosion zinc
○○
Check thermostat function
Flush cooling system
Adjust the tension of closed cooling system
pump belt
1
st
time
(and
thereafter
)
Intake / Exhaust system
Check the air cleaner element
Replace air cleaner element
Check exhaust system
(and
thereafter
)
Clean exhaust/water mixing elbow
Electrical system
Check and tighten electrical connections
Clean battery cables
Check the electrolyte level in the battery
Engine and mounting
Check for leakage af water and oil
(and
thereafter
)
Retighten all major nuts and bolts
○○
Check
tightness
of
mounting
bolts/
vibromounts
Check and adjusting intake / exhaust
valve clearance
Check and adjust the injection fuel pump
Remote control system, etc.
Check remote control operation
(and
thereafter
)
Test run generator set
In presence of this symbol it is possible to effect the technical support autonomously .
In presence of this symbol it is obligatory to effect the technical support in an our retailer /workshop authorized by MASE.