MLI Ultra 12/1250, 24/1250 – User and Installation Manual
Level below which the Capacity low event can
be triggered
Level below which the Cap. very low event can
be triggered
Level above which the Battery full event can be
triggered
Internal temperature of the MLI Ultra serves as
an event source
Internal temperature of the MLI Ultra serves as
an event source
Level below which the Voltage low event can be
triggered
Delay time to trigger the Voltage low event after
the level was reached
Last time fully charged serves as an event
source. To prevent damage the batteries must
be charged to the full 100% regularly.
It is a common misconception that Lithium-Ion
batteries should not be fully charged.
To optimize the battery cycle life, the Depth of
Discharge (DOD) is set to 80%.
CAUTION!
Changing the
DoD to 100%
will decrease
the cycle life.
Select this option if the auxiliary connector is
used to display the State of Charge.
Button to test if the battery switches-off when the
'battery safety'-conditions are met.
Button to test if the chargers stop charging when
the 'stop charge'-conditions are met.
Button to reset the MLI Ultra to its default
settings
Events tab
With MasterBus a device can be programmed to initiate an action at another connected device that
supports MasterBus. This is very helpful in automation of your system and is done by means of event-
based commands.
In the Events tab you can program the MLI Ultra to act as an event source. Events which occur during
the operation of the MLI Ultra will then trigger actions from other devices.