EasyManuals Logo

Mastervolt MLI Ultra User Manual

Mastervolt MLI Ultra
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
26
MLI Ultra 12/1250, 24/1250 User and Installation Manual
7. STORAGE AND CARE
If necessary, use a soft clean cloth to clean the MLI Ultra. Never use any liquids or acids.
The battery should be stored in a dry and well-ventilated environment. The rate of self-discharge is less
than 3% per month. High or low ambient temperature affects the self-discharge rate of the batteries and
natural aging.
If the battery will not be used for a period exceeding 3 months, we advise the following:
If external AC power is available switch off all loads and switch on the charger. Apply a float voltage
as specified in the following table.
Model
Float voltage setting
12V
13.5V
24V
27.0V
If no external AC power is available:
- Charge the battery to > 80% of its capacity before storage.
- Long press the Battery switch-button to open the safety relay, see page 7.
- Make sure MasterBus powering is not set to "Always on" (see Configuration tab in MasterAdjust).
CAUTION!
In this setup the batteries can be kept at least 6 months without maintenance. However, it is
highly recommended to charge the battery to over 80% of its capacity every 100 days.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mastervolt MLI Ultra and is the answer not in the manual?

Mastervolt MLI Ultra Specifications

General IconGeneral
BrandMastervolt
ModelMLI Ultra
CategoryCamera Accessories
LanguageEnglish

Related product manuals