EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
UL SENSOR N.C.UL SENSOR 10K
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
opening direction /id plug/operator
4
ground operator
3
Operator MUST be Properly GROUNDED
WARNING
connect chassis
to ground rod for
lightning protection
IMPORTANT: Operator MUST be grounded in lightning
prone areas or warranty will be VOIDED!
NOTE: Consult city codes for AC line wiring.
Beware of existing underground services.
Chassis
Ground
ID plug MUST be plugged in.
Proper grounding of this gate operator is a requirement for
LIGHTNING PROTECTION in lightning prone areas. To be effective,
ground connections should be made with a minimum 12 AWG, 600
volt insulated wire to a ground point within 3 feet of the gate
operator. The ground point must be at an electrical panel, a
metallic cold water pipe that runs in the earth, or a grounding rod.
WARNING
co
n
nect chassis
to
ground rod for
light
n
ing pr
otection
L
I
M
I
T
S
E
N
S
O
R
E
1/2
Re
p
la
c
e
Batte
r
y
O
N
/
O
FF
Ba
t
te
r
y
TE
S
T
Ba
t
t
e
ry
B
a
t
t
e
ry
IN
E
rror
F
Ba
tt
ery
M
odu
l
e
Ground
within 3 ft
of operator.
Any of the THREE Chassis Grounds can be used. They are located next
to the gear reducer. DO NOT remove any existing green ground wires.
1
2
3
Grounding Rod
OPEN RIGHTOPEN LEFT
MAX 1500 PRO
ID Plug
MAX 2200 PRO
ID Plug
MAX F18 PRO
ID Plug
MAX 1500
MAX 2200
MAX F18
SAFET
Y
SA
F
ETY
CENTER
CENTER
EXIT
EXIT
EX
I
T
P
W
R
ALARM
POWER /
SOLAR IN
BATTERY
INPU
T
OPENING
CLOSING
CLO
SIN
GO
P
EN
I
N
G
ERD
O
BD
POR
T
BLACK BOX
PRO
G
RA
MMI
N
G
SOLA
R MO
DE
P
R
O
GRAM
MOT
O
R
OV
E
R
LOAD
ER
D
M
O
TOR
OV
E
R
L
OAD
M
I
N M
A
X
O
F
F
M
AX
SENSE
M
AX
S
E
NS
E
BATTE
R
Y
BA
CK
UP
MO
DE
ERD SENSIT
IVITY
MOTIO
N CONTRO
L
OPE
N
GA
TE
SPEED
MA
G
L
OC
K
UL
ENT
RAP
PRIMAR
Y/
SECONDARY
LINK
STOP
CLOSE
MOTO
R
INPUTS
CLOSE
T
I
ME
R
MA
G
LO
CK
DEL
AY
JOG
B
AT
T
ERY
TES
T
BATTE
RY
IN
PUT
ER
R
O
R
BATTERY
IN
US
E
RE
P
LACE
BATTE
RY
LE
AV
E
CLO
SE
D
LE
AV
E
O
PEN
O
PEN
1
TI
M
E
BA
TTE
R
Y
VOLT
AGE
EF
1
/2
MA
N
U
A
L
RE
LEA
SE /
RES
ET
ID
PLUG
LINK
O
K
MODULE
PO
R
T
M
O
TO
R
PO
SITIO
N
I
NPU
T
S
SLID
E
R
LIMIT
SWI
N
G
LIMIT
G
ND
G
ND
GND
G
ND
GND
G
ND
G
ND
JOG
LEF
T
JOG
RIGHT
T
A
MP
E
R I
N
T
A
MPER N
O
GAT
E
D
I
S
AB
L
E
MA
N
U
AL
R
E
L
E
A
S
E
K
E
YPAD
/
CARD
GND
(-)
(+
)
GND
G
ND
MA
X O
P
E
N
F
I
RE
D
E
P
T
R
A
D
IO
GN
D
R
A
DI
O
S
IGN
AL
S
T
R
IKE
C
L
OSE
C
OM
C
O
M
S
T
O
P
OP
E
N
NO
NC
ID
PLUG
ERROR
24VDC O
UTPU
T
12VDC O
U
TPUT
G
ND
G
ND
G
ND
LOO
P PWR
O
F
F
PRIMARY
LEFT
O
N
/OFF
BATTERY
RIG
H
T
SECO
ND
A
R
Y
O
N
QUI
C
K
C
L
O
S
E
OP
E
N
LE
FT
O
P
E
N
RI
GHT
G
A
T
E
O
N
1
2
3
4
5
6
7
8
9
1
0
OFF
1
2
3
4
5
6
MI
N MI
N
MAX MAX
OF
F
O
F
F
2
.
5
s
ec
1.5 sec
FA
UL
T
S
OPE
RA
T
O
R
MATRIX III
OFF
MI
N
3
1
1
4
1
6
M
IN
16
1
2
9
7
3
1
1
4
1
2
9
7
U
L
S
ENSO
R
N
.C
.
UL
S
EN
S
O
R
10
K
POWER
M
OD
E
A
MOD
E
B
EXITL
O
OP
L
O
O
P
SAF
E
T
Y
CE
NT
E
R
SAF
E
TY
GATE OP
EN
CO
M
GA
TE CLOSED
MAXIMUM CONTROLS
SWINGER / SLI
DER
OPEN
RIGHT
OPEN
LEFT
Set the desired opening direction.
ID Plug Error: If ID plug is NOT
plugged in, board will constantly
beep and operator will NOT
function.
Operator:
Set operator to PRIMARY for a single operator installation.
Set EACH Matrix III board for desired operator positions
when bi-parting gates are installed.
NOTE: PRIMARY board settings will override secondary
board settings if a conflict in settings occurs.
IMPORTANT:
Remove breather pin
from gear reducer
BEFORE cycling
operator.
Breather
Pin
CAUTION
REMOVE
BEFORE
OPERATION
6
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Insta
ll Version 7a