EasyManua.ls Logo

Max 1500 PRO - Troubleshooting; USB Black Box Port; Test Entrapment Sensors

Max 1500 PRO
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
UL SENSOR N.C.UL SENSOR 10K
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
This page and the next 3 pages can help troubleshoot problems that might occur after installation is complete.
MAX
Flash Drive
usb black box port
Download a simple .txt file to troubleshoot gate operator errors and view event history.
Event type clarificaon:
INFO: informaonal message only
WARNING: unusual event but doesn't cause system malfuncon
ERROR: abnormal event, could cause system malfuncon
ENTRAP: entrapment detecon event
Event Report:
Fri 07/11/2014 10:59:41 INFO : Cycle Counter
Fri 07/11/2014 10:59:41 ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2014 10:59:37 INFO : Radio Input Deacvated
Fri 07/11/2014 10:59:36 INFO : Radio Input Acvated
Fri 07/11/2014 10:58:54 INFO : PRI_MC: Fully Open Posion Learned
Fri 07/11/2014 10:58:53 INFO : SEC_MC: Fully Open Posion Learned
Fri 07/11/2014 10:57:40 INFO : PRI_CIO: Communicaon Established
Fri 07/11/2014 10:57:38 ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:57:34 ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:57:21 INFO : Radio Input Deacvated
Fri 07/11/2014 10:57:21 INFO : Radio Input Acvated
Fri 07/11/2014 10:56:46 WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:36 INFO : SEC_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36 INFO : PRI_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36 WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Acvated
Event History Text Document Sample
obd
port
USB Phone
Adapter
Required
OR
Computer
Smart Phone
ob
d
port
Troubleshoot entrapment protection sensors:
1. Press and HOLD the STOP button & then the OPEN button together until beeping is heard, learn mode begins.
NOTE: DO NOT press the OPEN button before the STOP button or learn mode will NOT function.
3. Press STOP button again within 5 min. to end learn mode, beeping stops.
NOTE: If STOP button is not pressed within 5 min. learn mode automatically end after 5 min.
MOTION CONTROL
OPEN STOP
CLOSE
MOTION CONTROL
OPEN
STOP
CLOSE
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
UL SENSOR N.C.UL SENSOR 10K
O
NC
O
NC
O
NC
O
NC
O
C
.C.
.C.
C.
C
1. Plug MAX USB flash drive into OBD port. OBD LED will flash while file is downloading.
Remove flash drive after LED stops flashing (up to 5 minutes to download).
2. Plug flash drive into any computer USB port OR smart phone using a USB phone adapter.
The most recent 8000 events can be viewed. No special software required.
2. LEDs should be ON if an entrapment sensor is detected in EACH input.
If LEDs are NOT on, sensors have a problem.
Possible problems:
Photocells are out of alignment
Photocells are wired wrong - N.C. or N.O. depending on which
photocells are used, see specific mfg instructions.
Sensor is bad
test entrapment sensors
Unlearned Input
Monitored Power
Unlearned Input
Unlearned Input
Unlearned Input
Factory Learned Input
Factory Learned Input
IMPORTANT: Sensing
devices MUST be
powered by Matrix III
or they will NOT be
MONITORED.
P
NSOR N
N
N
N
N
N
.C
C
C
P
NSOR
N
N
N
N
N
N
.
.C
C
P
SOR
N
N
N
N
N
N
N.
.
P
SOR
R
N
N
N
N
N
N
N
SOR
R
R
N
N
N
N
N
N
SOR
R
R
R
N
N
N
N
OR
R
R
R
N
N
N
OR
R
R
R
R
N
OR
R
R
R
R
troubleshooting
19
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Instal
l Version 7a

Related product manuals