Max 1500 PRO - Adjust ERD Reverse Sensor

Max 1500 PRO
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXIT PWR
ALARM
SOLAR IN
OPENING
O
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
MAX
SENSE
S
ERD SENS
M
O
P
TEST
RESET /
MANUAL
RELEASE
ID
PLUG
MODULE
PORT
GND
GND
GND
MANUAL RELEASE
KEYPAD / CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY SECONDARY
ON
QU
I
CL
O
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN
MAX
FAULTS
OPERATOR
OFF
OFF
16
MIN
3
1
14 12
9
7
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
MA
T
SWI
N
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
CLOSINGOPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN/CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN/CLS 10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN MIN
MAX MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14 12
9
7
UL SENSOR N.C.UL SENSOR 10K
POWER
MODE A MODE B
EXIT LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
Quick Close
Turned OFF - Close timer will close the gate at its
selected time.
Turned ON - (In-ground loops required) OPENING gate
will stop and close after vehicle clears safety loop,
preventing UNAUTHORIZED entry.
Wire directly to
Matrix III board.
External
Loop
Detector
External Loop Detectors
In-Ground Loops
Connections
Loop Detector Rack
SAFETYCENTEREXIT
In-Ground Loops
loops & loop detectors
9
matrix III settings
10
Maglock Delay
Set to OFF
See next page to enable this feature.
Close Timer
1st click clockwise - Knob at MIN: 1/2 sec...
2nd click clockwise: 1 sec...
3rd click: 4 sec...
4th click: 8 sec... etc up to 60 sec. MAX.
Plug-In Loop Detectors
NOTE: DO NOT set Loop Detectors to HIGH sensitivity to avoid false trigger.
NOTE: DO NOT select the PULSED output option for Loop Detectors.
EDI
Loop Detector
EDI
Loop Detector
Low Current
Draw
ON
1
2
3
4
5
6
7
8
5 = Optim
u
m
Sens.
= Increase Sens.
= Decrease Sens.
DEF
LECTOMETER
P
OWER
ON = Normal
Power
OFF= No Power
LED INDI
CATORS
DETECT
ON = Detect
OFF= No Dete
ct
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON ON = Low
ON OFF
=
M
edium
-Low
OFF ON = M
ed
ium-H
i
gh
OFF OFF
= High
SW4 SW5 Output B
ON ON = Puls
e
on Entry
ON OFF
= B same as
A
OFF ON = Puls
e
on Exit
OFF OFF
=
Loop Faul
t
SW3
ON = Fail Secure
OFF = Fa
il Safe
SW6
ON = 2 Second Delay
OFF = No Delay
SW7
ON = Normal Pre
s
ence
OFF = Infinite Presenc
e
SW8
ON = Sens
itivity
Bo
os
t
OFF = No
S
ensitivity B
oost
L
oop Fault
1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashe
s
=25% chang
e
of Ind
uctanc
e
Both LED’s
F
lashin
g=
Current Loop Fault
PWR L
ED Flashing=
Pre
vious
Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMET
ER
SENS
R
ES
ET
POWER
DETECT
EDI
SENS
LMA1800
OPTIONS
1
2
3 4 5
6 7 8
ON
OPTIONS
ON
1
2
3
4
5
6
7
8
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOM
ETER
POWER
ON =
Normal Power
OFF=
N
o Powe
r
LED INDICATORS
DETECT
ON =
Detect
OFF=
N
o De
tect
2 Hz Fla
s
h=Delay Timin
g
SW1 SW2 Frequency
ON ON = Low
ON OFF = Medium-Low
OFF ON = Mediu
m-High
OFF
OFF
= High
SW4 SW5 Output B
ON ON = Pulse on Entry
ON OF
F = B
same as A
OF
F ON =
P
u
ls
e on E
xit
OF
F
O
FF
=
L
o
op F
ault
SW3
ON = Fail Secure
OF
F
= Fail Safe
SW6
O
N
=
2 S
eco
nd Dela
y
O
FF = No Dela
y
S
W7
O
N
=
Normal Pre
s
e
nc
e
O
FF = Infinite
P
res
en
c
e
SW8
O
N
=
Se
nsitivity B
o
os
t
OF
F
=
N
o
S
ensiti
vity Boo
st
Loop Fault
1 Flash = Open
Loop
2 Flashes= Shorted Loop
3 Flashes=
2
5% change
of
Induct
anc
e
Both LED’s
Flashing=
Current Loop Fault
PWR
LED
Flashing=
Previous Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECT
ED
I
SENS
LMA1800-LP
1 2
3
4 567 8
O
N
Safety loops wired in series.
Safety
Loop
Safety
Loop
Exit
Loop
Battery Back-Up Mode
LEAVE OPEN - After a power failure, gate will continue
to operate until battery power is drained. At this point,
the next open command, gate will remain OPEN. Gate
will automatically close after AC power is restored if
close timer is ON.
LEAVE CLOSED - After a power failure, gate will
continue to operate until battery power is drained.
At this point, gate will remain CLOSED.
OPEN 1 TIME - After a power failure, gate automati-
cally OPENS and REMAINS OPEN. When power is
restored, gate will automatically close.
Gate Speed
After gate positions have been
Learned”, the gate will cycle at
the speed set on “ GATE
SPEED” settings.
11
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Instal
l Version 7a

Related product manuals