20
(8) Cooling BT version: outdoor air temperature 35°C; in/out water temperature -3/-8°C. Fluid treated with 35% ethylene glycol.
(*) acvang the maximum Hz funcon
DATA SHEET FOR DESUPERHEATER UNIT
The performance with desuperheater is shown, under condions (1) of the technical data table, for water outlet temperatures of 45°C and 55°C
from the desuperheater.
Model
i-32V5C
Midi
capacity
Power
EER
Thermal
power DS
Perdite di
carico DS
Potenza
Potenza
EER
Potenza
termica DS
Perdite di
carico DS
0121
0126
0128
0132
The useful heads of the circulator associated with the desuperheater are shown below. The operang points shown in the previous table are
also represented.
Model i-32V5C Midi 0121, 0126 Model i-32V5C Midi 0128, 0132
Useful head of the circulator
Useful head of the circulator
0
10
20
30
40
50
60
70
80
90
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6
p [kPa]
ṁ [m
3
/h]
i-32V5C Midi 0121
p ToutDS=45°C ToutDS=55°C
0
10
20
30
40
50
60
70
80
90
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6
p [kPa]
ṁ [m
3
/h]
i-32V5C Midi 0128
p ToutDS=45°C ToutDS=55°C