i-32V5C MIDI Inverter Air/Water chillers with axial fan
7
GI module - system management. (oponal or for versions that require it).
The control secon includes:
Interface terminal with alphanumeric display;
Display funcon for set values, analogue inputs, fault codes, alarm history and parameter index;
Key on/o and alarm reset;
Key combinaons to force defrost and force pump to maximum speed;
Management of unit start-up from local or remote;
ModBus connecvity (oponal);
BMS connecvity via converter
BMS connecvity provision (ModBus/Bacnet/Knx/Lonworks) - oponal.
CONTROL AND PROTECTIVE DEVICES
All the units are standard supplied with the following control and protecve devices: return water temperature probe, installed on water return
pipe from the plant, working and anfreeze probe installed on the water delivery pipe to the plant, high pressure transducer, low pressure
transducer, inlet and outlet temperature probes from the compressor, compressor thermal protecon, fan thermal protecon, water side ow
switch protecng the evaporator, HP pressure switch.
WATER CIRCUIT
The series units are supplied with a built-in water circuit which includes: modulang circulator with high-eciency brushless motor (EEI≤0.23),
suitable for the use of chilled water and managed directly by the machine’s controller, plate heat exchanger, protecve ow switch, safety valve
(6 bar) to be connected to a collecon system and manual air venng valve.
2. DESCRIPTION OF VERSIONS AND ACCESSORIES
VERSIONS
The available versions are:
i-32V5C Midi - standard version chiller
i-32V5C-DS Midi - chiller with desuperheater
The unit with desuperheater includes the addion of a brazed plate type heat exchanger made of AISI 316 stainless steel, factory insulated using
closed cell material. This version allows to recover about 20% of the condensing heat otherwise lost and to use it to feed the aer-heang water
coils of an AHU or for a hot water ywheel or for any other process use.
i-32V5C-BT Midi - BT version chiller (for low water temperatures)
The BT version unit allows the operang range of the unit to be extended by cooling water to -8°C. In this case, a mixture of water and glycol is
used.
Order code
0110720#
00
Cooling only
54
Cooling only - BT
version
24
0121
25
0126
26
0128
27
0132
0
2 pipes
3
Desuperheater
circuit
0 Without injection
No silencing
Silencing
0
Without antifreeze
kit
4
Exchanger
resistance (KA1)
Without GI/GI2*
1
With GI/GI2 plant
operator
Modbus (CM)*
3 Modbus (CM) +GI
Standard
2
Thermomagnetic
circuit breakers
(IM)
0
No one
7
Battery with AERO
treatment (TR1)
No one
01
Standard
Accessory - Battery
treatment
Accessory 1 Code
RV
CT1
TA
Unit version Thermal capacity Water pipe configuration Antifreeze kit accessory
System management
module
Electrical variantsInjection (LT) Silencing
IV
SIL
AC1
MC
GI
EL3
TR
KA
* Not valid if TA=3
LIST OF ACCESSORIES