516532 B PUBLICATION DATE 1 JUN 2007.DOC PROGRAMMING MANUAL 41
Select View Fault Messages by the ENTER Button to see the
20 Fault messages kept in memory.
There are 20 Fault Messages kept in EEPROM memory.
Fault N° 1 : the last occurred Diagnostic message.
Fault N° 2 : the last –1 occurred Diagnostic message.
Fault N° 20 : the last – 19 occurred Diagnostic message.
D XXX : The Diagnostic message number
YYYYYYYYYY : The Diagnostic message name
If no messages are displayed, this means that no Errors have
occurred.
Press the YES and ENTER button if you want to
erase the Fault messages.
The Fault Statistics are an accumulation of Diagnostic
messages that have appeared over a long period.
The Statistics can be reset at the Service Menu, by a Reset
of the Cycle counter.
With this information, the technician has an indication of what
is in need of repair.
The List with Statistics.
No Drain : D8
Door Switch : D6 + D4 + D10 + D14
Bimetal / Spring : E17
No Fill : D7
Temp Sensor : D2
Level Sensor : D1
Mitsubishi Alarm : D12 + H61 + H62 + H63
PWM Drive Alarm : D11 + D12
Mitsu. Commun. Alarm : D11
View Fault Statistics
Service Faults
Erase Fault Messages No
Service Faults
View Fault Messages
Service Faults
1 Fault 1: D XXX: YYYYYYYYYYYY
2 Fault 2: D XXX: YYYYYYYYYYY
Y
3 Fault 3: D XXX: YYYYYYYYYYYY
4 Fault 4: DXXX: YYYYYYYYYYY
Y
Service Faults
1 No Drain 0x
2 Door Switch 0x
3 Bim/S
p
rin
g
0x
4 No Fill 0x
Service Statistics