3-68
1. To reinstall bearing house, position bearing
house and slide it onto the support rods.
2. Slide the bearing house over the shaft,
keeping shaft centered in bearing house.
3. Make sure the marks made on the bearing
house, align with the marks on the support.
4. Move the bearing house as close as
possible to the support at the back of tub.
5. When reinstalling the bolts, use thread lock
on the first 1/8th to 1/4” of each bolt.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.