11
320/407/500/600.41912-ENG
3.2.1. Electrical Power Supply
The Shear installation requires a 63A single or 32A three phase electrical supply. As part
of the installation, we strongly recommend the use of an earth leakage trip or Residual
Current Detector (RCD).
Ensure that the electrical supply is compatible with the Shear. Use armoured supply cable
complying with local regulations. Route the Supply Lead in such a manner as to leave it
freefromtrappingpointsandareaswhereitislikelytohindertheefcientoperationofthe
Shear, or cause a hazard.
The electrical supply to the Shear must only be installed by
an approved electrician.
3.3. Hydraulic Fluid
DonotruntheShearbeforellingtheHydraulicTankwith
Hydraulic Oil. Do not use a liquid other than Hydraulic Oil.
BeforestartingtheShearensuretheTankislledwithHydraulicOiltotheheavyblack
line on the Level Gauge.
Recommended oil types:
• BPHLP46;
• ShellTellusOil46;
• MobileDTE25;
• EssoNutoH46.
Monitor the oil temperature and do not allow it to exceed 65
Degrees Centigrade