19
320/407/500/600.41912-ENG
Turning the key to the Start position will initiate the following sequence:
• Cancel the Fuel Shut Off Timer, disengage the Pre-Heat Relay if it was engaged
and cancel the Pre-Heat Timer if it was active.
• Activate the Starter Relay.
Note the Key Must be held in the Start position until the engine is running, it can then be
released and will return to the Run position.
Note that if the Key is turned to the Start position before the Pre-Heat Relay is disengaged
the engine is unlikely to start.
4.3.2. To Stop the Shear
To stop a Diesel Shear, simply turn the key to the Stop position.
The Shear can also be stopped using the Emergency Stop (E-Stop) Button.
4.3.3. The Emergency Stop (E-Stop) Button
The Emergency Stop button should only be used to stop the Shear when there is a risk of
injury to the operator, for routine stopping of the Shear turn the key to the Stop position.
Once the E-Stop Button has been pressed it locks the Shear from restarting until it has
been reset. To reset the E-Stop Button, gently twist it and it should spring back to its
normal position.
Further information on the running and maintenance of the Engine is
presented in Lister Petter’s Operators Handbook, Part No: P027-08376.
Only operate and feed the Shear from the Right (Engine Side).