Extreme 9" Monitor/DVR System © 2014 McNeilus Truck and Manufacturing, Inc.
57
Preco Preview Radar System
• Detection Zone Set Up
Set up and test the PreView
®
Single Sensor system outdoors. It is important to make sure the sensor has a clear
eld of view, especially if it the detection zone set up must take place indoors. Two people are needed to set up
the detection zone.
1. With the parking brake applied, power up the PreView
®
system by turning on the vehicle's ignition and
placing the transmission in reverse. DO NOT start the engine unless it is necessary to engage reverse gear.
2. Make sure the SSV Extreme Monitor/DVR System display is illuminated and the system does not detect any
objects (all black/white indicator circles are off).
3. Have an assistant test the detection zone by walking in the direction of the arrows in approximately 3 ft.
(1M) increments, starting from direction 1, then 2, and nally 3 (see Figure 32).
4. Use the monitor to determine view points. Have the assistant place a trafc cone or other highly visible
object at the rst point of detection of the assistant on the monitor screen (Figure 32). Mark each point of
detection for each arrow direction. Repeat as necessary to conrm accurate detection zone.
5. The nal detection zone, as viewed through the monitor, should look similar to Figure 32. The arrows
indicate the points of detection of the assistant on the monitor.
~ 3 ft.
(1 m)
~ 3 ft.
(1 m)
PreView
CAM
Figure 32: Detection Zone as viewed through the monitor.