[EN] 12
If the humidity level has increased more than 3% above the target, the compressor will turn
on and the dehumidier will start to run again – the dehumidifying indicator will be solid. If the
humidity level is within 3% of the target, the dehumidier will go back to sleep and check the
humidity level in another 30 minutes.
If the current humidity level is within 15% of the target humidity level, the dehumidier
will default to low fan speed. If the current humidity level is 15% or more above the target
humidity level the dehumidier will default to medium fan speed.
Air Purication Mode: Hold the smart humidity button down for 2 seconds to enter Air
Purication Mode – the air purier indicator will show on the display in the top left corner.
In Air Purication Mode the dehumidier will not dehumidify, it will simply purify the air. This
mode is useful during the months when dehumidication is not required. To remove Air
Purication Mode, hold the smart humidity button down for 2 seconds – this will take you
back to Smart Humidity Mode.
Important! If a H13 HEPA lter is installed, the dehumidier will always be purifying the air
– it does not specically need to be in Air Purication Mode.
Smart Laundry Mode: Press the Smart Laundry Mode button once to enter Smart Laundry
Mode. In this mode, the dehumidier will default to a target humidity of 35%RH and high
fan speed. The laundry indicator will show on the display. The dehumidier will run in Smart
Laundry Mode for 6 hours, after 6 hours the dehumidier will turn o. To adjust the amount of
time left in Smart Laundry Mode, press the timer button. To stop Smart Laundry Mode press
the Smart Humidity button or turn the dehumidier o and on again.
If the dehumidier reaches a humidity level of 32%RH before the 6 hours is up, the
compressor will turn o to stop the air from becoming too dry, but the fan will continue to
run. The dehumidifying indicator will turn o. If the relative humidity increases to 38%RH the
compressor will turn back on. It will do this until the 6-hour timer is up.
Hold the smart laundry button for 2 seconds to enter WiFi mode . For further instructions
see page 6.
Timer: Use the timer button to set an ON or OFF timer. To remove either the ON or OFF
timer, press the timer button until you reach ‘00 hrs’.
Timer On: When the dehumidier is in standby mode, use the timer button to move between
1 and 24 hours in which the dehumidier will turn on. The interface will display the number of
hours in which the dehumidier will turn on e.g. ‘on 03 hr’. Please leave a one second pause
for the timer to be set.
Timer O: When the dehumidier is on, use the timer button to move between 1 and 24
hours in which the dehumidier will turn o. The interface will display the number of hours in
which the dehumidier will turn o e.g. ‘03 hr’ and ‘OFF’. If in Night Mode, the interface will
turn o. Please leave a one second pause for the timer to be set.