Page 32 65-J Diesel - Operator’s Manual
September 2022Section 7 - Operating Instructions & Pre-Operation Function Tests
Platform/Jib Functions Control Lever
ART_4733
The Platform/Jib Functions control lever controls the Platform Rotate and Jib
Lift/Lower functions. The control lever is fully proportional for both functions.
These functions are enabled by pressing the trigger on the front of the control
lever.
Test Operation
To test the Jib Lift/Lower function:
Squeeze the enable trigger, then pull the control lever back to raise
the jib.
Squeeze the enable trigger, then push the control lever forward to
lower the jib.
To test the Platform Rotate function:
Squeeze the enable trigger, then push the control lever left to turn the
platform clockwise.
Squeeze the enable trigger, then push the control lever right to turn
the platform counter clockwise.
Shutdown Procedure
ART_4734
When nished with the machine, place the platform in the stowed position.
Park the machine on a level surface.
Turn the Selector Key Switch to the OFF position and remove the key to
prevent unauthorized use. Always put the switch in OFF position when leaving
the machine at the end of the work day.
Carefully exit the platform using a constant three (3) point dismount/grip.