Page 14 92RT Scissor Lifts - Operator’s Manual
July 2020Section 6 - Function Tests and Operating Instructions
Lower Control Box: Turn key switch to BASE.
Diesel Engine
ART_3212
Flip switch to the top position to start the engine and then the switch will
return to ON position.
Cold Start: Flip the switch to ON position then wait as indicated in the
Preheat table before flipping switch to top position.
Preheat Table
Ambient Temperature Preheat Time
Above 50°F (10°C) 5 Seconds
50°F to 23°F (10°C to –5°C) 10 Seconds
Below 50°F (–5°C) 20 Seconds
20 Seconds = Limit of Continuous Use
Starting Engine from Upper Control Box
ART_3038
Upper Control Box: Turn the Key Switch to PLATFORM.
Diesel Engine
ART_3212
Upper Control Box: Hold switch in upper position until engine starts.
Release when engine starts then the switch will return to ON position.
Cold Start: Flip the switch to ON position then wait as indicated in the
Preheat table before flipping switch to top position.
Preheat Table
Ambient Temperature Preheat Time
Above 50°F (10°C) 5 Seconds
50°F to 23°F (10°C to –5°C) 10 Seconds
Below 50°F (–5°C) 20 Seconds
20 Seconds = Limit of Continuous Use
Base Controls Operation and Test