Megger LTW425 Specifications

General IconGeneral
Continuity Resolution0.01 Ω
Insulation Resistance Range0.01 MΩ to 999 MΩ
IP RatingIP54
TypeMultifunction Tester
Frequency Range45 Hz to 65 Hz
Dimensions203 mm x 148 mm x 78 mm
Power Supply6 x AA batteries
Insulation Test Voltages250 V, 500 V
DisplayDigital LCD
Test Voltage Range250 V to 1000 V

Summary

LTW300 Series Earth Loop Testers

User Guide Overview

Introduces the user guide for the LTW300 Series Earth Loop Testers.

Safety Information and Symbols

Critical Safety Warnings

Highlights essential safety warnings and precautions for instrument use.

Preparations and Basic Operation

Test Lead Connection Procedures

Loop Testing Methods Overview

Description of Loop Test Methods

Explains the principles behind No-Trip, High Current, and High Resolution loop tests.

No-Trip Test Details

Details the No-Trip test, its modes, and symbols indicating test status.

Specific Loop Test Procedures

High Current and High Resolution Tests

Covers High Current and High Resolution loop tests, including LTW425 specifics.

No-Trip Testing with Mains Socket Lead

Step-by-step guide for performing No-Trip tests using the mains socket lead.

Advanced Loop Testing Techniques

No-Trip Testing with RED/GREEN Leads

Instructions for No-Trip tests using the RED/GREEN test leads.

High Current Test Procedures

Details on performing High Current tests for Phase to Earth, Neutral, and Phase.

Additional Measurements and Error Sources

High Resolution Test and PFC Measurement

Covers High Resolution testing (LTW425) and Prospective Fault Current (PFC) measurement.

MaxZ, R1+R2, and Zref Measurements

Measuring MaxZ and Deriving R1+R2

Explains how to use the MaxZ function and derive R1+R2 values.

Measuring Zref

Details the procedure for measuring the reference impedance (Zref).

Voltage, Frequency, and Data Management

Storing and Recalling Test Results (LTW335)

Downloading and Deleting Test Results (LTW335)

Setup Menu and Configuration

Setup Option Selection

Guides on navigating the SETUP menu to configure instrument parameters.

Warning and Status Messages

Battery Status and Replacement

Technical Specifications

Safety Standards and Compliance

Accessories, Repair, and Warranty