EasyManua.ls Logo

Megger LTW425 - Safety Standards and Compliance; Safety Design and IEC61557 Compliance

Megger LTW425
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Safety
Designed to IEC61010-1, and IEC 61557 part3 1997
Designed for 300 V to Earth Category IV, With Phase to Phase voltages to 440 V.
Fuse protected to 600 V rms a.c.
A warning will be shown if applied voltage exceeds 440 V.
Damage will occur if applied voltage exceeds 500 V rms.
IEC61557
Complies with the following parts of EN61557, Electrical safety in low voltage systems up to 1000V ac and 1500V
dc- Equipment for testing, measuring or monitoring of protective measures:
Part1-General Requirements
Part3-Loop resistance
E.M.C. In accordance with IEC61326-1
Operational uncertainties: Refer to www.megger.com
Power supply
Battery: 8 x 1,5 V cells IEC LR6 type (AA alkaline).
Rechargeable: 8 x 1.2V NiMH cells
Battery life: 2000 consecutive tests
Mechanical
Weight: 1000g ±10% excluding test leads
Dimensions: 203 x 148 x 78 mm
14. Accessories and equipment
14.1 Supplied with appropriate instruments:
Optional accessories:
Alternatively specific units will be supplied with the following alternative to (ii) above:
1 x Mains plug test lead (AS/NZS 3112)
1 x Mains plug test lead CEE 7/7
Patents:
The loop testing technologies used in these instruments are subject to the following patent applications:
UK Patent no. 0518089.9
European Patent no. 06119110.2
US and Canadian patent application.

Table of Contents