EasyManua.ls Logo

Megger LTW425 - Technical Specifications; General Specification Details

Megger LTW425
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
13. Technical specification
13.1 General specification
Only values with tolerances or limits are guaranteed data. Values without tolerances are for information only.
Accuracy;
All accuracy statements are based on:
Ambient temperature: 23ºC ± C
Nominal source voltage: 230 V a.c ± 1%
Voltage measurement.
(a.c only) 50 V to 440 V
Accuracy: ±2% ±1 V
Frequency measurement
Range: 25 Hz to 99.99 Hz
Accuracy: ±0.1 Hz
Loop testing
NO-TRIP loop and high current loop test (LTW315)
Source voltage: 100 V to 280 V (50 Hz)
Display range: 0.01 Ω to 2000 Ω
Accuracy: ±5% ±0.03 Ω @ 230 V a.c. ±10% ±0,03 Ω @ 100 V a.c. and 280 V a.c.
NO-TRIP loop and high current loop test (LTW325, LTW335 and LTW425)
Source voltage: 50 V to 440 V (50 Hz)
Display range: 0.01 Ω to 2000 Ω
Accuracy: ±5% ±0.03 Ω @ 230 V a.c.
±10% ±0.03 Ω @ 100 V a.c. and 300 V a.c. (LTW325 and LTW425)
±10 ±0.02 Ω (LTW425)
±15% ±0.03 Ω @ 50 V a.c. (LTW325, LTW335 and LTW425)
Nominal test current:
No-Trip loop test 15 mA at nominal 230 V a.c supply
High current loop test 4 A at nominal 230 V a.c supply
EN61557 operational range: 0.30 Ω to 1000 Ω
High resolution loop test (LTW425 only)
Source voltage: 50 V to 440 V (50Hz)
Display range: 0.001 Ω to 2000 Ω
Accuracy: ±5% ±0.01 Ω
Nominal test current: 4 A at nominal 230 V supply
EN61557 operational range: 0.300 Ω to 1000 Ω
Prospective Fault Current (PFC)
Prospective fault current = Measured voltage / Loop resistance
Maximum range: No Trip mode: 20 KA
High current mode: 20 KA
Hi resolution mode: 40 KA
Accuracy is derived from loop test and voltage measurement.
Environmental
Temperature and humidity
Operating Range: -10°C to +60°C
Operating Humidity: 90% R.H. non-condensing at +40°C max.
Storage Range: -25°C to +70°C
Maximum altitude: 2000m to full safety specification
Dust and water ingress: IP54