EasyManua.ls Logo

Meiko EcoStar 545D - Parameter List

Meiko EcoStar 545D
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9625762 30 / 44
15.4 Parameter list
Par.
No.
Configuration
options
Use as
value
range
Unit
Factory
setting
Note
101
Wash program
Key 1
Parameters
1 .. 50
-
1
Allocate the wash program to the
key 1
Assignment adjustable
102
Wash program
Key 2
Parameters
1 .. 50
-
3
Allocate the wash program to the
key 2
Assignment adjustable
103
Wash program
Key 3
Parameters
1 .. 50
-
4
Allocate the wash program to the
key 3
Assignment adjustable
104
Rinse agent
Dosing quantity
Parameters
0.10 .. 1.00
ml/Liter
water
0.2
Value can be read from the rinse
aid container label (dependant on
water quality)
105
Rinse program
Dosing quantity
Parameters
0.1...
20.0
ml/Liter
water
2.0
Value can be read from the deter-
gent container label (dependant on
water quality)
106
Hardness degree
Parameters
0 .. 50
[°dH]
0
The quantity of soft water available
between two regenerations de-
pends on
the hardness of the water.
107
Beep ON/OFF
Parameters
0/1
-
1
Switch on/off acoustic ready mes-
sage
108
Mode
“Clear” display
Parameters
0/1
-
“Clear” display
0: via INFO 420, 520
1: display of special characters
111
Total Operation
time
Indication
Indication
5 figures
h
Operation time
query only
112
Total number of
wash cycles
Indication
5 figures
-
Wash cycles/loads,
query only
113
Total number of
wash cycles since
last reset
Indication
5 figures
-
Wash cycles/loads,
re-setting possible
114
Serial number
Indication
8 figures
-
Option for calling up works param-
eters
119
IR-communication
Parameters
0/1
-
1
It is possible to shut off communi-
cation via IR interfaces. (0)
120
Total number of
wash cycles Indi-
cation
Parameters
0/1
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION! All changes to ser-
vice parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, other-
wise factory settings will not be
loaded.
Without power supply reset, the in-
formation 123 will be displayed.

Table of Contents

Related product manuals