9625762 32 / 44
Par.
No.
Configuration
options
Use as
value
range
Unit
Factory
setting
Note
211
Fine adjustment
Post-rinse time
Parameters
0,0..0.9
sec.
0
0: FV 130.2 / FV 250.2
Figures after the decim al point in
P204
218
Shortage of rinse
aid
Parameters
0/1
0
Monitoring
Indication
219
Shortage of deter-
gent
Parameters
0/1
0
Monitoring
Indication
224
Shortage of deter-
gent
rinse aid dosing
pump
Parameters
0 .. 4
-
1
Definition: Energizing rinse aid
pump:
0 Rinse aid pump = 0; no signal
1 – Rinse aid pump; energizing ac-
cording to calculated running time
2 – Rinse aid pump = booster
pump;
energizing as booster
pump
3 – Rinse aid pump = wash pump;
energizing as wash pump
4 - Free
225
Energizing mode
Detergent dosing
pump
Parameters
0 .. 4
1
Definition: Energizing detergent
pump:
0 Detergent pump; no signal
1 Detergent pump; energizing ac-
cording to calculated running time
2 Detergent pump = pressure in-
creasing pump; energize as pres-
sure increasing pump
3 Detergent pump = wash pump;
energize as wash pump
4 Option detergent pump using
negative pressure dosing (only DV
80.2 and DV 200.2)
240
Detergent pump
activation mode
Parameters
0/1
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION! All changes to ser-
vice parameters will be
reversed.
Power supply reset must be carried
out within 5 minutes, otherwise fac-
tory settings will not be loaded.
Without power supply reset, the in-
formation 123 will be displayed.
241
A0-value
Parameters
0 …60
-
0
Only with disinfection machine no.
5 - 9 in parameter 201
321
Rinse agent
pump output
Parameters
0.1 ...
10
l/h
Rinse aid pump.
Output definition.
322
Detergent pump
output
Parameters
0.1 ...
20
l/h
Detergent pump
Output definition.
326
Pipe vent time
Rinse aid
Parameters
0 ... 255
sec.
Activate rinse agent pump tempo-
rarily to remove air from pipe.
327
Pipe vent time
Detergent
Parameters
0 ... 100
sec.
Activate detergent pump temporar-
ily to remove air from pipe.
347
Desinfection tem-
perature
Parameters
10 ...80
°C/°F
0
Only with disinfection machine no.
5 - 9 in parameter 201

Table of Contents