9625762 32 / 44
Post-rinse time
Figures after the decim al point in
0
0
gent
rinse aid dosing
pump
Definition: Energizing rinse aid
pump:
0 – Rinse aid pump = 0; no signal
1 – Rinse aid pump; energizing ac-
cording to calculated running time
2 – Rinse aid pump = booster
pump;
energizing as booster
pump
3 – Rinse aid pump = wash pump;
energizing as wash pump
Detergent dosing
pump
Definition: Energizing detergent
pump:
0 – Detergent pump; no signal
1 – Detergent pump; energizing ac-
cording to calculated running time
2 – Detergent pump = pressure in-
creasing pump; energize as pres-
sure increasing pump
3 – Detergent pump = wash pump;
energize as wash pump
4 – Option – detergent pump using
negative pressure dosing (only DV
activation mode
Effective only upon power supply
reset ON/OFF
ATTENTION! All changes to ser-
vice parameters will be
reversed.
Power supply reset must be carried
out within 5 minutes, otherwise fac-
tory settings will not be loaded.
Without power supply reset, the in-
formation 123 will be displayed.
Only with disinfection machine no.
5 - 9 in parameter 201
Rinse aid pump.
Output definition.
Detergent pump
Output definition.
Activate rinse agent pump tempo-
rarily to remove air from pipe.
Activate detergent pump temporar-
ily to remove air from pipe.
Desinfection tem-
perature
Only with disinfection machine no.
5 - 9 in parameter 201