9712938 26 / 68
Design and construction subject to change without prior notice!
The products are intended for permanent connection to the locally available power
supply and have been tested for the market accordingly. Any other form of electrical
connection is to be established by a licensed electrician.
Do not connect any additional consumers to the fuse protecting the machine.
• Re-tighten all terminal fixing screws before commissioning.
Note for frequency converter
If using a frequency converter within the area for the VDE 0160 / EN 50178, an all-
current sensitive FI type B must be installed before or instead of the existing fault
current circuit breaker FI type A.
For USA/Canada only:
The dishwashing machine must be installed in accordance with local regulations. In
the absence of any such regulations, the machine must be installed in accordance
with the applicable requirements in the National Electrical Code, NFPA 70, Cana-
dian Electrical Code (CEC), Part 1, CSA C22.1 and the Standard for Ventilation
Control and Fire Protection of Commercial Cooking Operations, NFPA 96.
7.2 Transport
Warning
Danger of injury from the machine falling over
The machine can fall over if transported incorrectly. People can be injured as a re-
sult.
• Transport work must be performed only by qualified persons.
• Please note safety instructions on the packaging.
• Always transport the machine only on the supplied wooden frame.
• Wear protective gloves and shoes.
The packaging is specifically designed to allow the appliances to be moved safely
and securely using a pallet jack or a sack truck. For safe transport, the dishwashing
machine is supported by a special square-timber frame.