9742146 24 / 42
If it is entered incorrectly, the code entry is cancelled, and the information code 122 is
displayed.
If you enter all the digits correctly, you will arrive at the chosen level, either service,
configuration or machine data.
15.3 Service level
You will find a list of service parameters at this level (parameter numbers 1xx). You can
view or modify the parameters here, or you can access the rinse aid and cleaner hose
ventilation feature.
is first shown at service level. This is equivalent to view/modify parameters (see 15.3.1)
this is equivalent to ventilate rinse aid inlet (see 15.3.2)
this is equivalent to ventilate detergent supply (see 15.3.3)
Press the I” button to move forwards or the “III” button to move backwards, and the
“accept” button to make a selection. You are now at the current level.
You can leave this level by pressing the “0” button.