29 / 42 9742146
15.4 Parameter list
Par.
Nr.
Configuration
options
Use as
Value
range
Unit
Note
101
Wash programme
Button 1
Parameters
1 .. 50
-
Allocate the wash programme to the 1 button;
Assignment adjustable
102
Wash programme
Button 2
Parameters
1 .. 50
-
Allocate the wash programme to the 2 button;
Assignment adjustable
103
Wash programme
Button 3
Parameters
1 .. 50
-
Allocate the wash programme to the 3 button;
Assignment adjustable
104
Rinse aid
Dosing quantity
Parameters
0.10 .. 1.00
ml/litre
water
The value can be read from the rinse aid
container label (depends on the water quality)
105
Detergent
Dosing quantity
Parameters
0.1...20.0
ml/litre
water
Value can be read from the detergent
container label (depends on the water
hardness)
106
Degree of
hardness
Parameters
0 .. 50
°dH
The quantity of soft water available between
two regenerations depends on the water
hardness
107
Beep on/off
Parameters
0/1
-
Switch acoustic ready message on/off
108
Mode empty
display
Parameters
0/1
-
Empty indicator
0: Via INFO 420, 520
1: Output of special characters
109
Partial/full
demineralisation
available?
Parameters
0,1,2
-
Partial/full demineralisation available?
0: No
1: Partial demineralisation (PD)
2: Full demineralisation (FD)
110
Hardness litres
per cartridge type
Parameters
0 .. 250
1000 L
"Replace cartridge" is displayed when the
cartridge's capacity
is reached (hardness litres/degree of
hardness)
(INFO 725) is displayed (only in the case of
PD)
111
Total operating
time display
Display
5 digits
H
Operating time, query only
112
Total number of
wash cycles
Display
5 digits
-
Wash cycles/loads, query only
113
Total number of
wash cycles since
last reset
Display
5 digits
-
Wash cycles/loads, resetting possible
114
Serial number
Display
8 digits
-
Option to query factory parameters
115
Condition of
remaining
cartridge capacity
Display
0 .. 100
%
Only for partial/full demineralisation:
PD: Indication in %
FD: 100 = OK;
0 = Replace
119
IR communication
Parameters
0/1
-
It is possible to shut off communication via IR
interfaces. (0)