Technical data
55
GB
Requirement: The appliance is ready for
operation.
1. Press the "Service" button as
well as the "Coee" direct key for more
than 2seconds to enter Service
mode2.
2. Press the "Service" button
repeatedly until the display for the
Venting function appears.
3. Press the "Service" button for
more than 2seconds to start venting.
» The Ready display ashes until
venting is ready to start.
» The Water display lights up and
requests you to remove the water
tank.
4. Remove the water tank and empty it.
» The Steam display lights up and
requests you to open the "valve".
5. Open the "valve".
» Water and steam escape from the
Cappuccinatore.
» The Steam display ashes.
» The Steam display lights up and
requests you to close the "valve".
6. Close the "valve".
» The appliance is vented and switches
o automatically.
8.2 Transporting the
appliance
ATTENTION
Freezing residual water can damage the
appliance.
Prevent the appliance from being
exposed to temperatures below 0°C.
Transport the appliance in the original
packaging. This avoids damage in transit.
Before transporting the appliance, carry
out the following activities:
1. Vent the appliance (see section8.1
Venting the appliance on page54).
2. Empty the drip tray and the coee
grounds container.
3. Empty the water tank.
4. Empty the bean container.
5. Clean the appliance (see section7.1
General cleaning on page48).
6. Package the appliance.
Information
When sending the appliance to Melit-
ta's service centres, it is not necessary
to send in the cup plate. This prevents
scratches during transport.
Do not use commercially available
adhesive and packing tapes to attach
loose parts. When detached, adhesive
residues remain on the appliance
which are dicult to remove.
8.3 Disposing of the
appliance
Appliances marked with this symbol
are subject to European Directive
2002 / 96 / EC for WEEE ( Waste Electri-
cal and Electronic Equipment).
Electrical appliances do not belong in
domestic waste.
Dispose of the appliance in an environ-
mentally friendly manner via suitable
collection systems.
9 Technical data
Technical data
Operating voltage 220V – 240V, 50Hz – 60Hz
Power consumption 1450W
Pump pressure max. 15bar
Dimensions
Width
Depth
Height
200mm
460mm
353mm