To run this function, after having entered the CONFIGURATION
MODE, push MENU/<< till when you don’t see
NUMBER OF SPLITS
Now push MEM to enter EDIT MODE, then press button
MENU/<< until the correct number of splits appears on the
display’s lower right corner.
Press button MEM to save the changes or button VIEW to
discard the changes.
Total Engine
running time
This function shows the engine total working time, which will be
displayed in hours and minutes, and let you clear that data.
To run this function, after having entered the CONFIGURATION
MODE press button MENU/<< until you’ll see
TOTAL RUNNING
To confirm your selection press button MEM a second time: the
sentence “Total are cleared” will appear on the display:
Press button VIEW to exit without deleting total running time
Temperature
alarm
This function sets the threshold temperature for the
thermocouple sensor that triggers the alarm when a dangerous
temperature has been reached. You should consult with your
engine manufacturer to determine what temperature threshold
should be set for your engine and thermocouple sensor.
To run this function, after having entered the CONFIGURATION
MODE, push MENU/<< till when you don’t see
TEMPERATURE ALARM