EasyManua.ls Logo

Mendota D30 - READ ME FIRST; INITIAL FIRING AND CURING PROCEDURE; HOT SURFACES ARE NORMAL; PERIODIC AND ANNUAL CLEANING ARE REQUIRED

Mendota D30
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85-03-01071 D30 DEEP TIMBER Page I
READ ME FIRST
1.1 INITIAL FIRING AND CURING PROCEDURE
This product requires an initial heat curing cycle during which some materials used in the manufacturing process will burn
off and the powder paint goes through a hardening cycle. During the initial curing phase, some smoke and odor will be
emitted. This is normal.
The installer should perform these initial curing cycle procedures as the final step in the installation process before
finishing materials are installed around this fireplace insert. See chapter 3.1.1 Mendota Fireplace insert Curing
Instructions. Read and follow all instructions given in this Chapter and perform the 3-step curing cycle.
After the 3-step curing cycle has been completed, all smoking will have stopped. Some slight odors may remain. With
subsequent use of this Fireplace insert, odors will slowly dissipate and disappear.
ODOR RISKS
If this appliance is not operated for an extended period ( three months or longer), when first fired
again, expect odors of burnt dust and lint; just like when turning on your home heating system for the
first time in the Fall.
1.2 HOT SURFACES ARE NORMAL
Be aware that the surface in front of, above and adjacent to this heater appliance can be too hot to touch. As long as all
required clearances to combustibles are met and the required finishing materials are used, this appliance will perform
safely. Note that the exposed surfaces immediately surrounding the Fireplace insert can have surface temperatures that
are too hot to touch. This level of surface temperature is considered normal and does not indicate any hazardous
situation.
WARNING: The supplied barrier screen must be installed, always, when this fireplace insert is in
operation. Do not place any object directly in front (within 60) or directly above (on the front edge
of the mantel). This is a heating appliance. Areas directly in front and above this appliance will be
very hot and can damage most household objects if placed too close. Keep Furniture pieces at least
60 away in front of the barrier screen.
1.3 PERIODIC AND ANNUAL CLEANING ARE REQUIRED
See Required Periodic Inspections, Chapter 6.1 and Required Annual Maintenance, Chapter 6.4. Periodic and Annual
cleaning and general services are required at least once a year in the Summer or early Fall. Cleaning pilot sparker rod and
pilot hood body is required at least once per year. Cleaning of burner ports, gas orifice areas is required once a year due
to insects’ nesting probability due to Mercaptan addition in Natural Gas (Mercaptan attracts insects).

Related product manuals