85-03-01071 D30 DEEP TIMBER Page 65
10 To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see Figure 5-1 Gas Valve). Blower speed
can also be turned down to reduce heat distribution.
NEVER “over fire" by increasing BTUH above Serial Number Plate specifications.
NEVER turn down (reduce) pilot flame below the minimum 325 millivolts.
11 Open windows for first two hours of operation.
NOTICE: Initial start-up will cause some NON-TOXIC "off gassing" of adhesives, binders, paint, etc. Most
nuisance odors will be
eliminated after the first 2 hrs. of operation, however, slight amounts may be present during the first 24
hrs.
5.5 TO TURN OFF GAS TO FIREPLACE INSERT
1. Turn OFF" the wall thermostat or timer control device. Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial to "OFF".
3. Turn off the internal manual shutoff valve in the appliance. See 3.6.6 Factory Installed Manual Gas Shutoff Valve.