EasyManua.ls Logo

Mendota D30 - HOW TO REMOVE DOORREQUIRED ANNUAL MAINTENANCE

Mendota D30
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85-03-01071 D30 DEEP TIMBER Page 71
6.4 HOW TO REMOVE DOORREQUIRED ANNUAL MAINTENANCE
See Chapter 5.7 What maintenance is required?
In addition to the Required Periodic Inspections, the following procedures must be performed each year by
a qualified installer, service agency or the gas supplier . Any adjustments to burner, pilot or logs must be
done by a qualified installer, service agency, or the gas supplier .
Clean all lint and dust build-up around the gas valve and blowers. Inspect the condition of any wiring for melting or damage.
Clean thermocouple and thermopile tips using emery cloth. Vacuum all burner ports and pilot assembly.
Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure the burner ports are
"open". Clean the pilot and under side of the logs for any Carbon deposits.
NOTE: Logs should be visually checked for Carbon "build -up". If heavy carbon deposits are visible on logs,
unit should be turned off and a qualified installer, service agency, or the gas supplier should be contacted.
Be sure logs are re-installed per instructions.
Check glass gasket seal. Visually inspect glass gasket, especially at the corners of the glass piece. Glass gasket is installed as a 4-
piece assembly. Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps
between gasket pieces can cause exhaust leaks and lead to acrid smell concerns.