EasyManua.ls Logo

Metal Work EB 80 - 3.3.5.7 Fail Safe Output; 3.3.5.8 Fault Mode Value

Metal Work EB 80
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53
3.3.5.8 Fault mode value
This function can be used to determine the value of the analogue output signal when communication with the Master is interrupted.
Each output is defined with 2 bytes.
Example: same as in table 3.3.5.3 User Full Scale
Object: No.1 04 Analog Outputs 02282S05
Parameter Function Default value Default
Par1
CH1:
- from BIT0 to BIT3: Signal range (0)
128
Disabled
- BIT5: Maximum monitor value (0)
Disabled
- BIT6: Minimum monitor value (0)
Disabled
- BIT7: Fail safe output (1) Fault mode
Par2 CH1:
User full scale (MSB) - -
Par3 CH1:
User full scale (LSB) - -
Par4 CH1: Minimum Value (MSB) 1
-32768
Par5 CH1: Minimum Value (LSB) 128
Par6 CH1: Maximum Value (MSB) 127
32767
Par7 CH1: Maximum Value (LSB) 255
Par8 CH1: Fault mode value (MSB) 0 0
Par9 CH1: Fault mode value (LSB) 0 0
Par10
CH2: - from BIT0 to BIT3: Signal range (0)
128
Disabled
- BIT5: Maximum monitor value (0)
Disabled
- BIT6: Minimum monitor value (0)
Disabled
- BIT7: Fail safe output (1) Fault mode
Par11 CH2:
User full scale (MSB) - -
Par12 CH2:
User full scale (LSB) - -
Par13 CH2: Minimum Value (MSB) 1
-32768
Par14 CH2: Minimum Value (LSB) 128
Par15 CH2: Maximum Value (MSB) 127
32767
Par16 CH2: Maximum Value (LSB) 255
Par17 CH2: Fault mode value (MSB) 0 0
Par18 CH2: Fault mode value (LSB) 0 0
Par19
CH3: - from BIT0 to BIT3: Signal range (0)
128
Disabled
- BIT5: Maximum monitor value (0)
Disabled
- BIT6: Minimum monitor value (0)
Disabled
- BIT7: Fail safe output (1) Fault mode
Par20 CH3:
User full scale (MSB) - -
Par21 CH3:
User full scale (LSB) - -
Par22 CH3: Minimum Value (MSB) 1
-32768
Par23 CH3: Minimum Value (LSB) 128
Par24 CH3: Maximum Value (MSB) 127
32767
Par25 CH3: Maximum Value (LSB) 255
Par26 CH3: Fault mode value (MSB) 0 0
Par27 CH3: Fault mode value (LSB) 0 0
Par28
CH4: - from BIT0 to BIT3: Signal range (0)
128
Disabled
- BIT5: Maximum monitor value (0)
Disabled
- BIT6: Minimum monitor value (0)
Disabled
- BIT7: Fail safe output (1) Fault mode
Par29 CH4:
User full scale (MSB) - -
Par30 CH4:
User full scale (LSB) - -
Par31 CH4: Minimum Value (MSB) 1
-32768
Par32 CH4: Minimum Value (LSB) 128
Par33 CH4: Maximum Value (MSB) 127
32767
Par34 CH4: Maximum Value (LSB) 255
Par35 CH4: Fault mode value (MSB) 0 0
Par36 CH4: Fault mode value (LSB) 0 0
Example of configuration
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Fail safe output
Minimum
monitor value
Maximum
monitor value
Reserved Signal range
Hold last state OFF OFF - 7 = 4/20 mA
0 0 0 0 0 1 1 1
bin 00000111 = 7 dec
GB