EasyManua.ls Logo

METREL EasiTEST MI 2087 AL2 - General Characteristics

METREL EasiTEST MI 2087 AL2
38 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MI 2087 AL2 EasiTEST Technical specification
38
Voltage Uci:
Measuring range...........................................(10 ÷ 100) V
Display range
(V)
Resolution
(V)
Accuracy*
0.00 ÷ 9.99
0.01
(-0/+10) % of r.
± 0.2 V
10.0 ÷ 100.0
0.1 (-0/+10) % of r.
*The accuracy is valid if:
q Mains voltage is stabile during the meas.
q PE terminal is free of interfering voltage
Uci voltage is calculated to trip-out current I.
Fault loop resistance and prospective
short-circuit current (LOOP L-PE, PSC)
Fault loop resistance RL-PE:
Measuring range......................................(0.20 ÷ 1999)
Display range
()
Resolution
()
Accuracy
0.00 ÷ 19.99
0.01
20.0 ÷ 199.9
0.1
200 ÷ 1999
1
±(5 % of r. + 5 D)
Prospective short-circuit current Ipsc:
Display range
(A)
Resolution
(A)
Accuracy
0.06 ÷ 19.99
0.01
20.0 ÷ 199.9
0.1
200 ÷ 1999
1
2.00k ÷ 19.99k
10
20.0k ÷ 24.4k
100
Consider
accuracy
of RL-PE
Ipsc calculation...........................Ipsc = UN1.06 / RL-PE
UN = 115V; (100V UL-PE < 160 V)
UN = 230V; (160V UL-PE 264 V)
Max. test current (at 230 V).....................................2.5 A
Nominal voltage range..........(100 ÷264) V / (45 – 65) Hz
Line resistance and prospective short-
circuit current (LOOP L-N, PSC)
Line resistance RL-N(L):
Measuring range.....................................(0.20 ÷ 1999)
Display range
()
Resolution
()
Accuracy
0.00 ÷ 19.99
0.01
20.0 ÷ 199.9
0.1
200 ÷ 1999
1
±(5 % of r. + 5 D)
Prospective short-circuit current Ipsc:
Display range
(A)
Resolution
(A)
Accuracy
0.06 ÷ 19.99
0.01
20.0 ÷ 199.9
0.1
200 ÷ 1999
1
2.00k ÷ 19.99k
10
20.0k ÷ 24.4k
100
Consider
accuracy
of RL-N(L)
Ipsc calculation.........................Ipsc = UN1.06 / RL-N(L)
................................UN = 115V; (100 V Uinp < 160 V)
................................UN = 230V; (160 V Uinp 264 V)
................................UN = 400V; (264 V < Uinp < 440 V)
Max. test current (at 230V).....................................2.5 A
Nominal voltage range..........(100 ÷440) V / (45 – 65) Hz
Voltage (Loop L-E, Loop L-N)
Display range
(V)
Resolution
(V)
Accuracy
0 ÷ 440
1
±(2 % of r. + 2 D)
Nominal frequency range.............................(45 ÷ 65) Hz
Frequency (Loop L-E, Loop L-N)
Display range
(Hz)
Resolution
(Hz)
Accuracy
45.0 ÷ 65.0
0.1
±(0.1 % of r. +1 D)
Nominal voltage range..................................(10 ÷ 440) V
6.2 General characteristics
Power supply...........6 V DC (4 × 1.5V battery IEC LR14)
Visual and sound warnings.........................................yes
Dimensions (w × h × d)..................(26.5 × 11 × 18.5) cm
Weight (without accessories, with batteries)...........1.8 kg
Display................................................LCD with backlight
Protection classification.........................double insulation
Over-voltage category........CATIII/300 V or CATII/600 V
Pollution degree.............................................................2
Degree of protection................................................IP 44
Working temp. range...................................0°C ÷ +40 °C
Nominal (reference) temp. range.............+10°C ÷ +30 °C
Max. humidity ..........................85 % RH (0 °C ÷ +40 °C)
Nominal (reference) hum. range.......40% RH ÷ 60 % RH
Auto power off............................................................yes

Related product manuals