Calibrateur multifonctions CX 1651
108 Manuel de l'utilisateur
Setting relative deviation
All function modes of the calibrator except frequency mode allow a relative deviation of output value from the
main data to be set using a separate display. Relative deviation is displayed in the “minor data” section of the
display and is designated with%= 00.0000 % “ symbol. The relative deviation can be entered using one of the
methods described above, e.g. using the numeric keyboard, cursor keys or the potentiometer.
Setting relative deviation using numeric keyboard
keep pressing the center cursor button until [ _ _ _ _ _ _ _ ] symbols appear under the relative
deviation value in the “minor data” section of the display
enter the desired deviation and confirm the value by pressing % display button or by pressing
ENTER on the numeric keyboard
the auxiliary line below the main data on the display displays the total value of output signal
including the unit of measurement
the value of the signal at output terminals is: the value indicated by the main display + %.
Maximum relative deviation which can be entered is ± 30.000 %.
The deviation can be positive or negative. If negative deviation is desired, press the display button labeled +/-. If
positive deviation is then desired, press “ +/- “ button again. The polarity of the relative deviation can be reversed
using the cursor buttons or the potentiometer as well.
Setting relative deviation using cursor keys
keep pressing the center cursor button until [ _ _ _ _ _ _ _ ] symbols appear under the relative
deviation value
press <, >, or button. The display now includes cursor marks which point to the active digit
and buttons can be used to change the active digit. <, > buttons can be used to change the
position of the cursor marks
to get to the default screen, keep pressing the center cursor button until there is no [ _ _ _ _ _ _ _ ]
under any value, or press EXIT button. All values can be set using the buttons or the potentiometer..
北京海洋兴业科技股份有限公司(证券代码:839145)
电话:010-62176775
网址:www.hyxyyq.com

Table of Contents

Other manuals for Metrix CX 1651

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metrix CX 1651 and is the answer not in the manual?

Metrix CX 1651 Specifications

General IconGeneral
BrandMetrix
ModelCX 1651
CategoryTest Equipment
LanguageEnglish

Related product manuals