MODEL HI 803
Operaon and Installaon Manual
Doc# 0296-0018 • REV R (July 2017)
REF.
INPUT
MODE CURSOR
HELP
SELECT
100 10K1K
FREQUENCY RANGE
Hz
FREQUENCY
RUN
STORE
AMPLITUDE
ABC
7
PQR
6
MNO
5
JKL
4
GHI
9
DEF
8
STU
1
VWX
2
YZ -
3
0
SPACE
PRINT
PAPER
ADV
HI 803
TRANSDUCER TEST SET
50 mV/g
RS-232

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Metrix HI 803 and is the answer not in the manual?

Metrix HI 803 Specifications

General IconGeneral
TypeInsulation and Continuity Tester
Test Voltage500 V, 1000 V
DisplayDigital
Measurement RangeInsulation: 0.01 MΩ to 10 GΩ; Continuity: 0.01 Ω to 1000 Ω
Power SupplyBattery

Summary

METRIX Model HI 803 Operation and Installation Manual

CHAPTER 1 - OVERVIEW

Description

Details the primary functions of the HI 803 TTS.

Capabilities

Lists selectable amplitude units and frequency units.

CHAPTER 1 - OVERVIEW (Continued)

Battery Operation

Details AC line or battery power usage.

CHAPTER 2 - SPECIFICATIONS

Specifications for the HI-803 TTS

Lists key technical specifications.

Measurement Uncertainty

Provides accuracy limits for acceleration, velocity, and displacement.

CHAPTER 2 - SPECIFICATIONS (Continued)

Transducer Sensitivity Range

Lists sensitivity ranges for accelerometers, velocity, and displacement.

CHAPTER 3 - INSTALLATION

Unpacking

Details steps for unpacking the instrument.

CHAPTER 3 - INSTALLATION (Continued)

Installation Procedures

Details steps for connecting transducers and testing.

Accelerometer (Charge Type)

Diagram for connecting charge accelerometers.

INSTALLATION OF MOUNTING BRACKET FOR AXIS A & B

Step-by-step guide for mounting bracket installation.

DI-103 Installation for A & B Axes

Procedure for installing DI-103 for A & B axes.

Transfer Test Data from TTS to PC

Describes how to transfer test data to a computer.

TTS to TUT Cable Connector Pin Out Diagram

Shows pin configuration for the input connector.

Triax Accelerometer (ICP Type)

Diagram for connecting triax ICP accelerometers.

Triaxial Accelerometer Installation

Details mounting bracket and cable installation.

DI-103 Installation for the C-Axis Tests

Procedure for installing DI-103 for C-axis tests.

DI-103A Installation for A & B- Axes Tests

Procedure for installing DI-103A for A & B axes.

DI-103A Installation for the C-Axis Tests

Procedure for installing DI-103A for C-axis tests.

Accelerometer - ICP Type

Diagram for connecting ICP accelerometers.

CHAPTER 4 - CALIBRATION

Required Test Equipment

Lists equipment needed for calibration.

CHAPTER 4 - CALIBRATION (Continued)

Displacement DCCalibration

Procedure for DC calibration of displacement.

Frequency Calibration Procedures

Steps to calibrate frequency response.

ADJUSTING THE REFERENCE OUTPUT (R113)

Procedure for adjusting the reference output.

REF Channel No Integ Calibration

Calibration for Reference Channel with no integration.

Channel A Calibration

Procedure for calibrating Channel A.

Charge Channel Calibration

Procedure for calibrating the Charge channel.

CHAPTER 5 - OPERATING PROCEDURES

Modes of Operation

Describes different operating modes like Setup, Monitor, Sensitivity.

CHAPTER 5 - OPERATING PROCEDURES (Continued)

Control and Indicators

Identifies front panel controls and indicators.

Monitor Mode

Used to vibrate TUT for testing and verification.

Sensitivity Mode

Setting up for sensitivity testing.

Sensitivity Test Procedures Volt Type Transducer

Steps for testing volt-type transducers.

Sensitivity Mode Testing for Displacement Type Transducer

Procedure for testing displacement transducers.

Dynamic Sensitivity Test

Measures displacement probe sensitivities at various gaps.

Static Linearity Test

Checks displacement probe output over its range.

Standard Checks for Transducers

Describes linearity and frequency response checks.

Setup Mode

Allows selection of units, date, time, and print options.

Monitor Mode Testing

Procedure for performing tests in Monitor Mode.

Sensitivity Test Setup

Entering transducer model, serial number, and mass.

Operating Procedures

General steps to start operating the TTS.

Related product manuals