WIZARDS Tab
WIZARDS-Restore
Use the WIZARDS - Restore page to restore a saved configuration from a backup file, or to
restore the factory default configuration.
Reset to Factory Defaults: Returns the SyncServer to its original factory configuration, remov-
ing ALL user-entered and operational information including password, IP addressing, GPS
position, and time zone. See SYSTEM - Factory Reset (on page 53).
Restore Last Backup from SyncServer: Restores the configuration as it was when the user cre-
ated the most recent backup configuration file. The backup file is located in the SyncServer’s
nonvolatile memory.
Restore From USB flash drive: Restores the configuration from a backup file located on a USB
drive attached either of the USB ports on the front panel.
Restore backup from workstation hard-drive or network directory: Restores the configuration
from any backup file located on local or network drive accessible to the browser.
Note: Resetting or restoring the configuration reboots the SyncServer. If LAN1 is configured
to use DHCP, the DHCP server may assign a new IP address to LAN1. If needed, use the
front panel STATUS button to view the new IP address on the LAN1 STATUS screen.
WIZARDS-Upgrade
Use WIZARDS - Upgrade to update the SyncServer software.
SyncServer upgrade packages are available at http://www.microsemi.com/ftdsupport
and then following the links from the Support menu
Users are required to register in order to download software. Some export restrictions may
apply.
To upgrade the software, download the upgrade package file to:
n A file area that is accessible to the web browser.
n To a USB flash drive, or to an area where it can be copied to a USB flash drive.
Then use WIZARDS - Upgrade to copy the upgrade file to the SyncServer and perform the
upgrade.
Note: The SyncServer automatically decompresses the software upgrade ".tar" file. Please
do not decompress the ".tar" file prior to upgrading the SyncServer.
997-01520-02 Rev. G2.......................................................................... Page 71