24 Port Gigabit Ethernet PoE Switch User Manual Page 35 of 72
________________________________________________________________________
©2014 MICROSENS GmbH & Co. KG Hamm/Germany www.microsens.com
Parameter description
System Priority:
System priority is used in determining the root switch, root port and designated
port. The switch with the highest priority (lowest numeric value) becomes the
STP root switch. If all switches have the same priority, the switch with the lowest
MAC address will then become the root switch. Select a vale from the drop-down
list box.
The lower the numeric value you assign, the higher the priority for this system.
Default: 32768
Hello Time:
This is the time interval in seconds between BPDU configuration message gener-
ations by the root switch. The allowed range is 1 to 10 seconds.
Default: 2
Max Age:
This is the maximum time a switch can wait without receiving a BPDU before at-
tempting to reconfigure. The allowed range is 6 to 40 seconds.
Default: 20
Forward Delay:
This is the maximum time (in seconds) a switch will wait before changing states.
The general rule: 2 * (Forward Delay 1) >= Max Age >= 2 * (Hello Time + 1)
Default: 15
Force version:
Select RSTP or STP protocol from the drop-down list box.
Function name
RSTP Port Configuration
Function description
Enable or disable RSTP protocol on the ports that are selected and set path cost.

Other manuals for Microsens MS400830M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microsens MS400830M and is the answer not in the manual?

Microsens MS400830M Specifications

General IconGeneral
BrandMicrosens
ModelMS400830M
CategoryNetwork Router
LanguageEnglish

Related product manuals