24 Port Gigabit Ethernet PoE Switch User Manual Page 46 of 72
________________________________________________________________________
©2014 MICROSENS GmbH & Co. KG Hamm/Germany www.microsens.com
Parameter description
Mode:
Controls whether Broadcast Strom Protection is enabled (as a whole)
Packet Per Second:
It is a threshold. When the broadcast packet traffic in a second is higher than the
threshold configured, Broadcast Strom Protection will disable the port.
Unlock Time:
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action is to shut down the port).
State:
Show the status on the port.
Protocol Enabled:
Controls whether Broadcast Strom Protection is enabled on this switch port
Unlock port:
When ticking the port, port locked will be opened and turned into unlocked. If not
ticking the port, Port maintains locked.